<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-27 06-24-57
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
87.90 MHz 5/5, 37 dBuV R-VYSOC
Pilot RDS Phase Difference
0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
3 kHz 32 kHz 17829 1,0489
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-3,2 dBr -1,26 dBr -0,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-VYSOC " 2D09 9 (Varied) 1 0 1 1 6:24, 27.07.2024
RT
"Zpravy z regionu - rozhovory - dobre rady - souteze "
AF EON
87.9, 90.1, 96.5 MHz -
FM Scope Max at: 32 kHz MIN: 3 kHz % above 77 kHz: 1,0489 Acquired: 2024/07/27 6:24:54 Total samples: 17829 Equivalent time: 0:14:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: -0,4 dBr MIN: -3,2 dBr AVE: -1,26 dBr % above 0,2 dBr: 0,0 Last value: -1,1 dBr (2024/07/27 6:24:53) 06:12 06:14 06:16 06:18 06:20 06:22 06:24 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality